Threaded Style Filter Installation
The most common cause of failure for threaded mount filters is improper installation. Please use the following guidelines when installing filters to insure years of error-free service.
1. Do not exceed the recommended mounting torque specification shown in the table below.
2. The use of 60/40 RMA solder is recommended for attachment to terminal. Soldering iron tip temperature should be maintained at 500° F and soldering should be completed in 3 to 5 seconds. When possible, use a heat sink between terminal and filter body.
3. Avoid twisting, bending, or applying unnecessary forces on the terminal. If cutting is required it should be done prior to mounting in a manner that would apply minimum stress on the unit.
Thread Size |
Maximum Mounting Torque |
"A" |
"B" |
"C" |
"D" |
"E" |
| 4-40 UNC |
1.5 Inch Lbs. |
.187 |
.062 |
.220 |
.120 |
.015 |
| 6-32 UNC |
2 Inch Lbs. |
.187 |
.062 |
.283 |
.146 |
.017 |
| 8-32 UNC |
5 Inch Lbs. |
.250 |
.075 |
.281 |
.146 |
.018 |
| 12-32 UNEF |
8 Inch Lbs. |
.312 |
.075 |
.378 |
.220 |
.022 |
| 12-28 UNF |
8 Inch Lbs. |
.312 |
.075 |
.378 |
.220 |
.022 |
| 1/4-28 UNF |
8 Inch Lbs |
.312 |
.090 |
.402 |
.262 |
.025 |
|