Corry Micronics ISO 9001 Certified Product Shots











Filter Installation Tips:

Threaded Style Filter Installation
The most common cause of failure for threaded mount filters is improper installation. Please use the following guidelines when installing filters to insure years of error-free service.

1. Do not exceed the recommended mounting torque specification shown in the table below.

2. The use of 60/40 RMA solder is recommended for attachment to terminal. Soldering iron tip temperature should be maintained at 500° F and soldering should be completed in 3 to 5 seconds. When possible, use a heat sink between terminal and filter body.

3. Avoid twisting, bending, or applying unnecessary forces on the terminal. If cutting is required it should be done prior to mounting in a manner that would apply minimum stress on the unit.

Thread
Size
Maximum
Mounting Torque

"A"

"B"

"C"

"D"

"E"
4-40 UNC 1.5 Inch Lbs. .187 .062 .220 .120 .015
6-32 UNC 2 Inch Lbs. .187 .062 .283 .146 .017
8-32 UNC 5 Inch Lbs. .250 .075 .281 .146 .018
12-32 UNEF 8 Inch Lbs. .312 .075 .378 .220 .022
12-28 UNF 8 Inch Lbs. .312 .075 .378 .220 .022
1/4-28 UNF 8 Inch Lbs .312 .090 .402 .262 .025

                                                                                                                                                                                                                                                               


Privacy Policy